ElectroThermal DesignThermal Analysis / Report

// Thermal Analysis · Standalone

ETD 1kW Concept
Thermal Analysis Report

A steady-state and transient CFD/FEA thermal evaluation of the Kilowatt Concept enclosure and heat-pipe cooling system, prepared for Example Report.

POWER_TOTAL 1.0 kW
HEMT_MAX 186.05 °C
COOLING SYSTEM EFF 75.1%
STATUS Steady-State + Transient
Prepared By
ElectroThermal Design
Prepared For
Example Report
Email
contact@electrothermaldesign.com
Preferred Contact
xxxxxxxxxxx
Deadline
XX.XX.XXXX XX:XX
Date / Time Stamp
3.19.2023 · 15:05
Service Package
Thermal Analysis_Standalone
Deliverables
1kW Concept Deliverables

// Table of Contents

// Section 1

1Introduction

1.1 Report Structure

Introduction — a brief outline of the unit under analysis, and a restatement of all prerequisite data provided to ETD, including significant definitions and final deliverables.
Simulation Overview — the raw data pertaining to the initialization and execution of the thermodynamic simulation(s).
Simulation Deliverables — a collection of the graphical/visual deliverables derived from the simulation.
Conclusion — a brief summary highlighting key results and insights, as well as suggestions for improving thermal performance.

1.2 Unit Overview

The goal of this report is to assess the thermal performance of the Kilowatt Concept enclosure and cooling system. The Kilowatt Concept is a modularized three part design. The unit features a main chassis which houses the power and control components. On the bottom of the main chassis are two docks, designed to receive the RF modules. These modules are left- and right-hand specific, each containing a 4-pipe heatpipe system with the capacity to transfer up to 440 W per module. The final assembly measures roughly 12.9" × 11.1" × 6.4" (32.8 × 28.2 × 16.5 cm) and weighs 21.3 lbs (9.65 kg). A Technical Explosion Animation is available as a visual aid.

The Kilowatt Concept cooling apparatus is a heat-pipe heat exchanger + forced-air system, referred to as the heatpipe system throughout this report. Eight partially embedded heatpipes draw up to 800 W of power from heat sources within the modules. The exposed end of each heatpipe features a 90° bend, creating a vertical section populated by 54 press-fit sheet fins acting as radiators. An additional heatsink sits on the top plane of the main chassis. Both the chassis heatsink and the heatpipe fins are cooled by a Sanyo Denki 9WL1424P1H001 fan located at the rear, set up as an outlet (pulling) fan providing ≈147 CFM.

REF · Full assembly render▸ Model
Isometric render of the Kilowatt Concept unit
Main chassis (top), control panel (front), and RF module docks (bottom).

1.2.1 Main Chassis

The main chassis is the largest subassembly in the Kilowatt Concept. It consists of an interior cavity to house power and control hardware, a machined heatsink, and an interface plate. This report concentrates on the power cavity and its subsequent heatsink. Located within the power cavity are five individual power supply units (PSU #1–#5), mated to the surface opposite the main chassis heatsink.

1.2.1 · Main Chassis, Cutaway▸ Model
Transparent cutaway of the main chassis showing heatsink, fan, and control panel
1.2.1.1 · Power Cavity▸ Model
Cross-sectional view showing the power cavity
Cross-sectional view of the empty power cavity.
1.2.1.2 · Power Supplies▸ Model
Location of the five power supply units within the power cavity
PSU #1–#5, within the power cavity.
1.2.1.3 · Main Chassis Heatsink▸ Model
Top-down view of the main chassis heatsink
Top-down view showing the main chassis heatsink.

1.2.2 Fan Assembly

The fan assembly is composed of the 9WL1424P1H001 Sanyo Denki fan and four sheet-metal brackets, located at the rear of the unit. The space between the main chassis and the fan assembly — where the heatpipe fins reside — is called the fan chamber. The San Ace 140W 9WL1424P1H001 is an IP-68 aluminum-framed fan.

1.2.2 · Fan Assembly▸ Model
Fan assembly, front-isometric view
1.2.2.1 · Fan Chamber▸ Model
Top-down view of the fan chamber, free-space area highlighted
Top-down view — the fan chamber / heatpipe fin area is highlighted.

1.2.3 RF Modules

The RF Modules are detachable subassemblies where the HEMTs (primary heat sources) live, and therefore house the heatpipe system. There is a left-hand module and a right-hand module — exact mirror images of each other — each containing two HEMTs (HEMT #1/#2 left, HEMT #3/#4 right).

1.2.3 · RF Modules▸ Model
RF modules, open, with heatpipe fin stacks detached above
1.2.3.1 · HEMTs▸ Model
Top-down view of the HEMT locations within the RF modules
Top-down view of the HEMT locations within the RF modules — HEMT #1/#2 (left module), HEMT #3/#4 (right module).

1.3 Simulation Model

The cooling system pulls air from the front of the unit, across the main chassis heatsink, through the fan chamber, and exhausts it out the rear. This configuration requires internal fluid-flow analysis, meaning the unit must be air-tight aside from the intake orifices. A "simulation-friendly" 3D model was therefore created prior to solving:

1.3.1.1 Control Panel

True Model
True model, with control panel
Simulation Model
Simulation model, control panel removed and sealed

The control panel is completely removed and the gap in the main chassis is filled, creating a seamless power cavity.

1.3.1.2 Fan Assembly

True Model
True model, with fan and guard
Simulation Model
Simulation model, fan replaced with a solid cylindrical placeholder

The sheet-metal brackets are replaced with solid surfaces; the fan guard is discarded and the Sanyo Denki fan is replaced with a solid, cylindrical place-holder.

1.4 Prerequisite Information

The following prerequisite information was defined and agreed upon by ETD and the customer prior to initialization.

Materials
Part IDMaterial
Housing (TYP)Aluminum 6061-T651
PCB (TYP)FR-4 + Copper (8-layer)
Heatpipe FinsAluminum 6063-T6
Heat Sources
Part IDDissipation Rate
HEMT #1200 W
HEMT #2200 W
HEMT #3200 W
HEMT #4200 W
DC Power Supply #130 W
DC Power Supply #240 W
DC Power Supply #360 W
DC Power Supply #440 W
DC Power Supply #530 W
Environmental Conditions
Ambient Temp30 °C
RadiationN/A
Altitude of Operation0 m
Boundary Conditions
Ambient Airflow0 m/s
Mounting InterfaceN/A
Thermal Interfaces
Interface MaterialLocation + Thickness
MG 8616 Therm GreaseUnder DC power supplies — 0.02 mm
Indium SpringUnder FETs — 0.1 mm
Cooling Systems
Heatpipe Heat ExchangerAppendix 5.2.1
Forced Convection — Sanyo 9WL1424P1H001Appendix 5.2.2
Transient Analysis
Set Run-Time30 mins — full power
Components of Interest
ComponentSpecs
GaN HEMT — Wolf Speed CGHV96130F (4×)Appendix 5.3.1
DC Power Supply — XXXXXXAppendix 5.3.2
Report Deliverables

3D Heat Map ✓ · Cross-sectional Heat Map ✓ · Global Max/Min Chart ✓ · Conclusion + Suggestions ✓ · Fluid Dynamics Package (add-on) ✓ · Cooling System Performance — Fan Performance, Heatpipe Efficiency (add-on) ✓ · Transient Analysis — 3 min & 30 min full-power runs (add-on) ✓ · Advanced Component Analysis — GaN HEMT, Typ. (add-on) ✓

// Section 2

2Simulation Overview

2.1 Analysis Environment
Software ProductFlow Simulation 2022 SP1.0, Build 5482
CPU TypeIntel Core i7-10750H @ 2.60 GHz
RAM32675 MB / 25728 MB
OSWindows 10+ (10.0.19044)
2.2 Model Information
Model NameSIM-ETD 1 kW Concept.SLDASM
Project NameETD 1 kW — Thermal Analysis
2.3 Project Comments
Unit SystemMetric
Analysis TypeInternal Fluid Flow
Number of SimulationsThree — Steady-State · Transient (180 s) · Transient (1800 s)
2.4 Size of Computational Domain
AxisMinMaxSize
X-0.142 m0.142 m0.284 m
Y-0.053 m0.111 m0.164 m
Z-0.227 m0.096 m0.324 m

2.5 Simulation Parameters

2.5.1 Basic Mesh Dimensions
Cells in X18
Cells in Y10
Cells in Z22
Analysis Mesh Granularity
Total Cell Count916,941
Fluid Cells337,321
Solid Cells579,620
Partial Cells239,512
2.5.2 Additional Physical Calculation Options
Heat Conduction in SolidsOn
Flow TypeLaminar and turbulent
Time-Dependent AnalysisSim #1 Off · Sim #2 On · Sim #3 On
GravityOn
RadiationOff
HumidityOff
Default Wall Roughness0 µm
2.5.3 Material Settings
PartMaterial
Working FluidAir (Sea Level)
Housing (TYP)Aluminum 6061
HEMT CasingAlumina (96%)
ScrewsSteel Stainless 302
HEMT BaseCopper
DC Power Supply Gap FillerMG 8616 Thermal Grease II
HEMT Gap FillerIndium
Heatpipe FinsAluminum 6063 T6
RF BoardsPCB 8-layers
HEMT DieGallium Arsenide
HEMT Die InterfaceSolder (Sn 63% / Pb 37%)
2.5.4 Initial Conditions
Static Pressure101,325 Pa
Ambient Temperature30.00 °C
Velocity Vector0,0,0 m/s
Default Solid MaterialAluminum 6061
Initial Solid Temp30.00 °C
Turbulence Intensity / Length2.00% / 0.002 m
2.5.5 Boundary Conditions
Outlet Fan TypeExternal Outlet Fan (pulling air)
Fan CurveSanyo Denki 9WL1424P1H001
Outlet FacesFan exhaust — unit rear
Pressure OpeningsTop-front intake, left-rear, right-rear
Environment Pressure101,325 Pa
Boundary Layer TypeTurbulent
2.5.6 Volumetric Heat Sources
Component GroupTotalBreakdown
HEMTs (4×, Wolf Speed CGHV96130F)800 W200 W each
DC Power Supplies (5×)200 W30 / 40 / 60 / 40 / 30 W
2.5.7 Engineering Goals (Volume Goals — Solid Temperature, Maximum)
GoalComponentsUse in Convergence
HEMT Max TemperatureWolf Speed CGHV96130F HEMT (4×)On
Power Supply Max TemperatureDC Power Supplies (5×)On
Heatpipe Fin Max TemperatureHeatpipe Heat Exchanger fins (54×)On
2.6 Sim #1 — Steady-State
Calculation Time1939 s
Iterations140
WarningsNone
2.6 Sim #2 — 30 Minute Transient
Calculation Time6226 s
Iterations600
WarningsNone

// Section 3

3Simulation Deliverables

3.1 Steady-State Goals
NameValueProgressCriteriaDelta
HEMT Max Temperature186.05 °C100%3.2533451.13312594
Power Supply Max Temperature67.38 °C100%1.105231860.19700122
Heatsink Fin Max Temperature72.96 °C100%1.289034941.06605264

3.2 Global Min–Max Table

ParameterMinimumMaximum
Temperature [°C]29.92186.05
Temperature (Fluid) [°C]29.92118.23
Temperature (Solid) [°C]30.00186.05
Pressure [Pa]101,056.41116,018.12
Velocity [m/s]018.786
Mach Number00.05
Heat Flux [W/m²]09,765,708.08
Heat Transfer Coefficient [W/m²K]6.465e-072621.63
Acoustic Power Level [dB]049.70

Full 27-row parameter table (density, vorticity, shear stress, enthalpy flux, etc.) retained from the source Flow Simulation export; abridged here to the parameters referenced in Section 4.

3.3 Steady State Results

3.3.1 Surface Temperatures (3D Heat Map)

3.3.1.1 · Full Exterior▸ Rendered
3.3.1.2 · RF Modules▸ Rendered
3.3.1.3 · Power Cavity + Main Chassis Heatsink▸ Rendered

3.3.2 Cut Temperatures (Cross-Sectional Heat Map)

3.3.2.1 · X-Y Plane (Thru HEMTs)▸ Rendered
3.3.2.2 · Y-Z Plane (Thru Right RF Module)▸ Rendered

3.3.3 Advanced Component Analysis — HEMT Junction to Unit Exterior

Temperature plotted as a function of displacement, starting at an HEMT junction (x = 0 mm, 184.18 °C) and following a linear path to the RF module exterior (x = 14.224 mm, 79.67 °C).

SOLVE · T(x) — Junction → Exterior▸ Analyzed
HEMT junction to unit exterior temperature vs displacement
Typical HEMT, junction-to-exterior temperature vs. displacement.
Path of Displacement▸ Model
Cross-sectional plot through an HEMT showing the path of displacement
A cross-sectional plot through an HEMT, showing the path of displacement referred to in the graph above.
HEMT #1
HEMT #1 junction to exterior chart
HEMT #2
HEMT #2 junction to exterior chart
HEMT #3
HEMT #3 junction to exterior chart
HEMT #4
HEMT #4 junction to exterior chart

Per-device breakdown across all four GaN HEMTs (goal component group, Section 2.5.7).

3.4 Fluid Dynamics Package

3.4.1 Flow Trajectories

3.4.1.1 · Top-Down▸ Rendered
3.4.1.2 · Side Profile▸ Rendered

3.4.2 Pressure Gradients

3.4.2.1 · Main Chassis Heatsink▸ Rendered
3.4.2.2 · Fan Chamber▸ Rendered

3.4.3 Cooling System Performance — Fan Curve

The chart below shows the 9WL1424P1H001 fan curve (theoretical, no back pressure) against the derated operating curve. Equilibrium was reached at the steady-state operating point.

9WL1424P1H001 Outlet Fan▸ Operating Point
9WL1424P1H001 fan curve and operating curve
Result: airflow of 0.0495 m³/s at a back pressure of 172.57 Pa.

3.4.3.2 Heatpipe System Efficiency

Efficiency is assessed on a system level — heat load transported from the HEMTs, through the eight-heatpipe network, and released to ambient via the fins — rather than treating heatpipes as isolated entities. Heat load out was determined via a Flow Simulation surface parameter study on the heatpipe fins (convective heat transfer rate).

Surface Parameter Study — Fins▸ 600.622 W
Surface parameter study on the heatpipe fins, 600.622 W convective heat transfer rate
Efficiency Calculation
Efficiency equation, 75.1%

3.5 Transient Results

3.5.1 Transient Surface Temperatures (Heat Flow Animations)

Simulation playback of surface temperature, captured across the 3-minute and 30-minute full-power transient runs.

3.5.1.1 · HEMTs▸ Rendered
Typical GaN HEMT, surface temperature over time.
3.5.1.2 · Power Cavity▸ Rendered
Power supply cavity, surface temperature over time.
3.5.1.3 · Heatpipe Fins▸ Rendered
Heatpipe heat exchanger fin stack, surface temperature over time.
3.5.1.4 · Main Chassis Heatsink▸ Rendered
Main chassis heatsink, surface temperature over time.

3.5.2 Transient Cut Temperatures (Cross-Sectional Heat Flow Animations)

3.5.2.1 · X-Y Plane (Thru HEMTs)▸ Rendered
Cross-sectional cut through the HEMT plane, temperature over time.
3.5.2.2 · Y-Z Plane (Thru Right RF Module)▸ Rendered
Cross-sectional cut through the right RF module, temperature over time.

3.5.3 Transient Component Analysis — Temperature vs. Time

Component Temperature Rise — 3 Minutes▸ Analyzed
Component temperature rise over 3 minutes, full power
HEMTs settle within ~30 s owing to their low thermal mass.
Component Temperature Rise — 30 Minutes▸ Analyzed
Component temperature rise over 30 minutes, full power
Power supplies and heatpipe fins continue trending upward through the full 1800 s window, approaching but not reaching the steady-state solution.

// Section 4

4Conclusion

The purpose of this report is to provide a data-driven analysis of the thermal capabilities of the Kilowatt Concept housing and cooling system under a 1000 W thermal load. A series of thermodynamic simulations were conducted using SolidWorks Flow Simulation software.

The results reveal the cooling system successfully diffused the 1000 W heat load — all critical components reached steady-state without exceeding maximum operating temperatures. The GaN HEMTs, the highest and most dense heat source, reached a collective maximum junction temperature of 186.05 °C, comfortably within the 9WL1424P1H001 datasheet's maximum recommended junction temperature of 225 °C. The power supplies reached a collective maximum of 67.38 °C (PSU #3, center) — low enough to be a non-priority.

The heatpipe cooling system is the heart of the unit, cooling four 200 W HEMTs across only 0.5 in² of footprint each. Section 3.4.3.2 calculates an overall efficiency of 75.1% — over 600 W of heat load taken directly out of the HEMTs and dispersed to ambient — allowing the unit to remain within operating limits while retaining a compact, lightweight frame.

4.1 Suggestions

Any marginal improvement in thermal performance is most likely to come from adjusting parameters of the heatpipe system or elements directly related to it.

4.1.1 Adjusting the Profile of the Heatpipe Fins

The current profile features 54 fins at 0.06" thickness. Reducing thickness to 0.03" would allow doubling the fin count to 108 with no increase in fan back pressure — likely yielding a 5–10 °C drop in HEMT maximum temperature.

4.1.2 Increasing Airflow to the Heatpipe Fins

The pressure drop across the main chassis heatsink (~150 Pa) sits close to the fan's operating point (172.6 Pa). Creating a higher free-space ratio in the chassis heatsink profile (fewer fins, spaced further apart) would reduce back pressure, shift the operating point down the fan curve, and generate more airflow to the heatpipe fins — trading a rise in power-supply temperature (non-priority) for a drop in HEMT temperature.

Fan Curve / Operating Point
Fan curve and operating point
Pressure Gradient — Main Chassis Heatsink
Pressure gradient across the main chassis heatsink

4.1.3 D-Shaped Surface Heatpipes

Raising the heatpipes to the module surface and switching from circular to D-shaped cross-sections would let the HEMTs sit directly on the heatpipe, reducing heat slippage into the module base. Trade-offs: reduced manufacturability (custom D-shaped pipes) and reduced structural durability (partially vs. fully embedded).

// Section 5

5Appendix

5.1 Cooling System Specs

5.1.1 Heatpipe System

Eight heatpipes total, four per RF module, working fluid 70% water / 30% ammonia. Each pipe: 0.30" diameter, 5.50" horizontal evaporator section (heat in), 90° bend to a ~4.25" vertical condenser section (heat out). Conservatively rated at 110 W/pipe → 880 W system capacity.

5.1.1.1 · Transparent Heatpipe System▸ Model
Transparent view of all eight heatpipes across both RF modules
Transparent view of the 4 heatpipes embedded within a single RF module, condenser sections rising to the fin stack.
Heatpipe Route — Depth
Heatpipe embedment depth dimension callout
Heatpipe Route — Diameter
Heatpipe diameter dimension callout
Heatpipe Fin Profile
Fin Size4.00" × 1.75"
Material6063-T6 Aluminum, 0.06" thick
Fins per RF Module27 (54 total)
Fin Spacing0.09"
Free-Space Ratio0.59
5.1.1.2 · Heatpipe + Fin Assembly▸ Model
Assembled heatpipe and fin stack, single RF module

5.1.2 Sanyo Denki 9WL1424P1H001 Fan

Datasheet: publish.sanyodenki.com — San Ace E, p.286

5.2 Component Specs

5.2.1 Wolf Speed CGHV96130F GaN HEMT

Wolf Speed CGHV96130F GaN HEMT, packaged part render

Datasheet: assets.wolfspeed.com/cghv96130f.pdf

5.3 Material Data

5.3.1 Gases — Air
Specific Heat Ratio (Cp/Cv)1.399
Molecular Mass0.0290 kg/mol

Temperature-dependent dynamic viscosity, specific heat, and thermal conductivity curves (−200 °C to 3000 °C) sourced from the Flow Simulation engineering database; see source datasheet for full curve data.

5.3.2 Solids
MaterialDensitySpecific HeatThermal ConductivityMelting / Ref Temp
Aluminum 60612700 kg/m³Non-linear (see curve)Non-linear (see curve)582.00 °C
Alumina (96%)3720 kg/m³880.0 J/kgK24.70 W/mK1700.00 °C
Steel Stainless 3027900 kg/m³500.0 J/kgK16.30 W/mK1400.00 °C
Copper8960 kg/m³Non-linear (see curve)Non-linear (see curve)1083.05 °C
MG 8616 Thermal Grease II2400 kg/m³120.0 J/kgK1.78 W/mK180.00 °C
Indium7310 kg/m³Non-linear (see curve)Non-linear (see curve)156.60 °C
Aluminum 6063 T62700 kg/m³900.0 J/kgK209.00 W/mK
PCB 8-layers2391 kg/m³1073.0 J/kgK0.28 / 32.70 W/mK (axial/radial)726.85 °C
Gallium Arsenide5316 kg/m³325.0 J/kgKNon-linear (see curve)1237.00 °C
Solder (Sn63/Pb37)8400 kg/m³150.0 J/kgK50.90 W/mK189.79 °C